Our Latest News

FPE Station: Installation, Maintenance, Selection & Practical Tips

FPE Station: Installation, Maintenance, Selection & Practical Tips

An FPE station (Fire Prevention & Extinguishing) is a first-response point equipped with firefighting tools and emergency accessories, ready to tackle the onset of a fire. Its role is crucial in emergency situations—a well-equipped and properly positioned FPE station can limit fire spread until firefighters arrive, safeguarding lives and property. This technical article provides practical guidance on correct installation, periodic maintenance, common mistakes to avoid, and choosing the right FPE station to ensure this vital safety element performs its duty.

Fully equipped FPE station
Fully equipped FPE station. A correctly installed and maintained unit ensures swift intervention in case of fire.

Types and Configurations of FPE Stations

There are several types of FPE stations, tailored to different environments and needs. Broadly, we distinguish:

  • Fixed vs. mobile FPE stations: A fixed station is usually a metal cabinet mounted securely on a wall or pedestal, while a mobile station is on wheels or portable, so it can be relocated near potential fire zones. Mobile stations are useful in large or changing spaces (like construction sites or outdoor warehouses) where fire risk areas move and flexibility is needed.

  • Indoor vs. outdoor stations: Indoor units (e.g., along corridors or industrial halls) resemble wall-mounted hydrant boxes or cabinets, protecting equipment from dust and ready for fast deployment. Outdoor stations are usually metal cabinets treated for corrosion resistance, placed in yards, parking lots, or open areas. They must withstand weather and temperature variations while ensuring quick access to tools even in rain or frost. Romanian regulations recommend at least one outdoor station per 1,000 m², meaning larger areas may require multiple stations.

  • Equipped vs. empty cabinets: Manufacturers offer fully equipped FPE stations (complete with all necessary tools and accessories) or empty cabinets with only the enclosure and mounting brackets, allowing the user to add equipment. For instance, you might purchase just the metal cabinet and later add a fire extinguisher, sand bucket, shovel, axe, etc., or choose a factory-equipped kit ready to install. Companies like MAR‑INA Prodprest offer both configurations—empty, minimally equipped, or complete kits with sand box and tools. The choice depends on what you already have and whether you prefer a ready-made or customizable setup.

Proper Installation of an FPE Station

Installing an FPE station requires careful attention to legal and practical placement standards. Key steps include:

  • Choosing the right location: Position it in a strategic, clearly visible, and easily accessible spot. Regulations stipulate placing stations along escape routes, corridors, hallways, or near exits—avoiding hidden corners or locked rooms. Ideally, mount it near the main exit so it’s accessible from indoors and outdoors. Ensure no obstacles block access (furniture, stacked materials, or parked vehicles). A standard FPE sign or symbol must be present for quick identification.

  • Physical mounting: For wall-mounted cabinets, use strong fasteners (screws, anchors) at ergonomically correct heights. Internal equipment, like extinguishers, should be positioned 1–1.5 m from the floor. Taller cabinets (~1.8 m) should be elevated on legs (~10–15 cm) to avoid contact with damp floors. Freestanding units should be anchored to walls or floors to prevent tipping, especially outdoors in wind. Ensure the cabinet is plumb and test internal supports and doors to open smoothly under load.

  • Weather protection: For outdoor units, choose cabinets made from corrosion-resistant thick metal, powder-coated for rust prevention. Ideally, install under a small overhang. Raise it above ground on concrete or paving blocks to prevent water pooling. In seismic areas, secure additional anchoring against earthquakes.

  • Ensuring quick access: If it has a lock, keep it unlocked during operating hours or install a "break-glass-to-release-key" box or breakable lock used in emergencies. Tools must be easy to remove quickly—no complicated locking mechanisms that could delay action.

  • Signage and staff training: After installation, apply the standard red symbol (axe, bucket, extinguisher) on the door if not pre-printed. Add an arrow sign nearby to guide users. Provide all staff with clear instructions and conduct demonstrations showing where the station is and how to use each tool. A nearby instruction panel with extinguisher steps and emergency numbers is also helpful.

Periodic Maintenance & Inspection of the FPE Station

Once installed, an FPE station requires regular upkeep. Law mandates building managers ensure all fire defense tools remain operational through scheduled checks. Here's how to keep your station in top shape:

  • Monthly visual inspection: Check that all tools are present and in good condition. The extinguisher gauge should be in the green zone, seals intact, hoses undamaged, and all metal tools clean and rust-free. If a sand bucket is included, ensure it’s dry and refill if used or contaminated. Also check door hinges and fasteners, lubricating if necessary.

  • Extinguisher servicing: All extinguishers must undergo annual inspection by certified personnel. A service company should check weight, pressure, seals, and integrity, applying a tagged label with the date. Replace or recharge extinguishers that are expired, used, or faulty. Visually check them quarterly and shake dry-powder extinguishers to prevent sedimentation.

  • Tool maintenance: Axe and pick handles must be solid and heads firmly fixed—replace cracked handles. Sharpen blades as needed. Check crowbars and rakes for deformation and apply a light oil layer to prevent rust. Clean shovels and so on. Inspect hydrant keys: clean threads and lubricate periodically. Ensure sand box is sealed to keep sand dry.

  • Cleanliness and order: Keep the interior tidy and free from unauthorized items. Dust tools and shelves. Repaint the cabinet if the red finish fades or rust appears. Faded markings reduce visibility and can signal neglect.

  • Drills & scenario testing: Periodically conduct fire drills including use of the FPE station—test door opening, tool extraction, extinguisher operation. Document any difficulties (e.g. locked cabinet latch) and promptly correct them.

  • Records & responsibilities: Assign a responsible person to oversee inspections and maintenance. Keep a control register noting dates, findings, and actions (e.g. "March 10, 2025 – replaced expired P6 powder extinguisher, refilled 5 kg sand, lubricated door hinges"). This register serves both internal tracking and external inspection by authorities. Only certified equipment with CE marking or CNCIR approval may be used.

Common Mistakes to Avoid with FPE Stations

Even with good intentions, some common errors occur:

  • Poor placement or inadequate signage: Installing the station in an obscure corner or locked room, or without proper signage, can render it useless. Solution: follow placement guidelines and clearly mark with standard signage. Conduct walkthroughs with new staff to show station locations.

  • Blocked access: Items often accumulate in front of stations (e.g. pallets, furniture, parked vehicles), blocking access. Solution: mark a 1–2 m clear zone with yellow tape labeled “Do not obstruct – FPE access.” Outdoors use bollards or painted outlines.

  • Locked cabinet with inaccessible key: Keeping the station locked but the key at reception causes delays. Solution: if locking is necessary, use break-glass access or specialized quick-release locks, ideally unlocked during business hours.

  • Insufficient or mis-matched equipment: Inadequate kit (e.g. only sand buckets near electrical risk areas) is ineffective. Solution: assess fire risks and include appropriate extinguishers (CO₂ for electrical fires, foam for combustibles) and tools.

  • Neglected periodic checks: Expired extinguishers, rusted tools, missing parts—common issues over time. Solution: enforce strict maintenance schedules, assign responsibilities, and keep records.

  • Lack of staff training: People may hesitate or misuse equipment in stress. Solution: conduct hands-on training, demonstrate tools and extinguisher use, and simulate scenarios like extinguishing a bin fire.

Tips for Choosing the Right FPE Station

Selecting the right station requires evaluating your space and legal obligations. Consider:

  • Risk analysis & area size: Identify fire hazards, materials, size, layout, and hydrant availability. Small workshops may need only a cabinet with a P6 powder extinguisher, fire blanket, shovel, and sand bucket. A large industrial hall (e.g. 1,000 m²) handling machinery demands a more robust station with multiple extinguishers (powder, CO₂), hydrant hose, full tool set, and protective equipment.

  • Environmental conditions: Outdoor stations need galvanized or aluminum cabinets with weather-resistant coatings. Some models include ventilation to prevent condensation. Indoor units demand less weather resistance but should still be sturdy. In unheated spaces, use sand instead of water to prevent freezing. In dusty or chemical environments, choose airtight cabinets with gaskets.

  • Equipment configuration & compatibility: Ensure the cabinet can accommodate all planned tools, such as wheeled extinguishers or hydrant hoses. Check manufacturer data sheets for internal layouts showing where tools attach to avoid crowding.

  • Quality & certification: Choose certified products with durable construction (strong welds, robust hinges, correct thickness). Internal tools should be CE marked. Avoid makeshift or artisanal cabinets—they often lack necessary features. Invest in purpose-built units for long-term reliability.

  • Optional extras: Consider models with alarm buttons or smoke detectors, integrated first-aid kits, or dual cabinet for hydrant plus extinguisher. In public buildings, post emergency assembly point signage near the station.

  • Budget & long-term planning: While empty cabinets are cheaper, you’ll need to buy tools separately. Fully-equipped kits cost more but ensure compatibility. Plan for ongoing expenses like annual servicing and consumables (sand, first-aid supplies).

Tip: If unsure, consult a fire safety specialist or your equipment supplier. MAR‑INA Prodprest offers expert guidance and multiple configurations. Explore available models on the FPE Stations category page.

Conclusion

A correctly selected, strategically placed, and impeccably maintained FPE station is fundamental to fire safety in any building or industrial space. From secure installation to timely inspections, every detail matters so that in a crisis, the system works flawlessly. Following regulations and applying practical tips ensures the FPE station becomes an active resource capable of saving lives and reducing damage. Prepare in advance, choose wisely, and build a culture of prevention—this is the key to making “METAL and FIRE under CONTROL” more than a slogan, but a reality at your workplace.

    Leave a Reply